Series | LPX-E3 Series | |
Model | E3X1 | E3X2 |
Scanning Radius |
0.05 - 25m (Recognition(≥70% Reflectivity)) 0.05 - 10m (Warning(≥10% Reflectivity)) 0.05 - 4m (Alarming(≥2% Reflectivity)) |
0.05 - 40m (Measurement(≥70% Reflectivity)) 0.05 - 40m (Recognition(≥70% Reflectivity)) 0.05 - 15m (Warning(≥10% Reflectivity)) 0.05 - 5m (Alarming(≥2% Reflectivity)) |
Blind Range | 0.05m | |
Sampling Rate | 20Hz | 10/15/20Hz |
Angular Resolution | 0.225° @ 20Hz |
0.1125° @ 10Hz 0.17° @ 15Hz 0.225° @ 20Hz(Typical) |
Field Monitoring Data Output | IO / RS485 / Ethernet | |
Number of Field Sets | 64 Field Sets @ 20Hz | 64 Field Sets @ 20Hz(Typical) |
48 Field Sets @ 15Hz | ||
32 Field Sets @ 10Hz | ||
Simultaneous Field Sets Monitoring | 1(incl. 3 fields) | |
Communication Interface | USB Type-C | |
Point Cloud Outputs | NIL | Ethernet / Serial |
Range Resolution | 10mm | |
Measurement Accuracy | ± 30mm | |
Operating Temperature | 0℃~50℃ |
Remarks:The sensor does not constitute a safety component as defined by relevant legislation on machine safety
X represents the N, P, S, R, C, D, T, and E series